Environmental data for PolarEye™ and any lab experiment

The Data Logger records the room and the world around every session, on PolarEye™ or linked to other laboratory equipment and recording devices.
$5,000 academic · $10,000 enterprise · Part no. DL1A-00
Standalone Data Logger S: $6,000 academic · $12,000 enterprise · Part no. DL1A-0S
Build your system, then buy online or generate a quote.
Why Record the Room
In a classic study, three labs used identical apparatus and protocols and still got systematic differences in mouse behavior.1 A machine-learning analysis of 8,034 baseline thermal-nociception observations found the experimenter mattered more than genotype, with season and humidity among the ranked factors.2 Von Frey responses can change by 80% over a single day.3
Most of these variables are never written down. Data Logger records them automatically, alongside every session, so they become data instead of noise.
Sensors built into the device record light, sound, temperature, barometric pressure, humidity and vibration.
External data adds pollen, outdoor air quality, indoor air quality, moon phase, outside temperature and weather conditions to every session.
Optional remote in-cage sensors measure temperature and humidity in up to 8 cages.

Light · Evidence: strong
What it measures: light level and light-dark transitions in the room, so you know when lights went on and off and whether the dark phase was really dark.
Why it matters: light sets the mouse circadian clock through melanopsin-containing retinal cells, and intensity, timing and spectrum all shape physiology and behavior.46 Even dim light at night shifted when mice ate (55.5% versus 36.5% of food in the light phase) and increased weight gain.5
In MouseOS™: light history is attached to each session as a covariate, light leaks during the dark phase are flagged, and Virtual Control Groups can match on lighting conditions.

Sound · Evidence: moderate
What it measures: sound level in the room during each session.
Why it matters: noise is a recognized source of stress for laboratory rodents.79 Rodents hear well into the ultrasonic range, and a survey of laboratory equipment found 24 of 39 sources emitted ultrasound, some of them entirely above human hearing.8
In MouseOS™: sound level is logged per session, loud events are flagged against the timeline, and Virtual Control Groups can exclude noisy sessions from matching.

Temperature · Evidence: moderate
What it measures: room temperature throughout each session.
Why it matters: typical vivaria run at 20–24 °C, below the mouse’s thermoneutral zone, so animals spend energy staying warm.10 That mild cold stress can change the physiology a model is meant to measure.11
In MouseOS™: temperature becomes a session covariate, excursions outside your set range are flagged, and Virtual Control Groups can match on temperature.

Barometric Pressure · Evidence: strong in pain models
What it measures: barometric pressure and how it changes before and during each session.
Why it matters: lowering pressure by 20 mmHg worsened mechanical allodynia in nerve-injured rats but not in controls,12 an effect that depends on the inner ear.1315 In neuropathic mice, a single 20 hPa drop did nothing, but three consecutive drops raised von Frey sensitivity and corticosterone.14 Most of this work comes from one research group and applies to injured animals.
In MouseOS™: pressure and recent pressure change are attached to every session, pain-model sessions after falling pressure are flagged, and Virtual Control Groups can match on pressure history.

Humidity · Evidence: moderate
What it measures: relative humidity during each session.
Why it matters: humidity appears among the ranked environmental factors in large nociception datasets, though there it travels with season.2 Humidity inside the cage runs higher than in the room, rises in summer and climbs with the number of animals housed.16 It is a known, uncontrolled variable, and the only way to account for it is to record it.
In MouseOS™: humidity is stored as a session covariate, out-of-range readings are flagged, and Virtual Control Groups can match on it.

Outside Weather · Evidence: weak
What it measures: local outdoor conditions, such as humidity, pressure and wind, at the time of each session.
Why it matters: in 2,658 people with chronic pain, pain was modestly associated with humidity, pressure and wind.17 That evidence is from humans, not rodents. We capture outside weather so the question can be tested in your own animals, not because it is known to change their behavior.
In MouseOS™: outside weather is attached to each session as an optional covariate you can include or ignore in any analysis.

Thunderstorms · Evidence: pets yes, rodents untested
What it measures: whether a storm was passing over the facility during a session.
Why it matters: any pet owner knows thunderstorms and fireworks can frighten dogs and other pets. In one survey of nearly 16,000 companion animals, 74% were frightened by fireworks, most often hiding, shivering or cowering.24 Video of the same dogs on a fireworks night and a quiet night showed ears pulled back, more pacing and more panting.25 Lab rodents may react the same way, but no published study has tested it yet.
Recording storms lets you test that in your own data. If one group behaved strangely during a storm, you can see it and give a data-based reason for excluding that group or analyzing it separately, instead of guessing.
In MouseOS™: storm days are event-tagged on the session timeline, so you can filter them out or compare them directly.

Location & Season · Evidence: moderate
What it measures: facility location and date, which link each session to season, local climate and pressure, and let you compare sites.
Why it matters: seasonal variation in laboratory animals is documented, though the mechanisms remain largely undetermined, especially since vivarium day length is set by a timer.18 Common strains such as C57BL/6 produce little melatonin, one reason seasonal effects can differ by strain.19 Season and humidity also rank among factors in large nociception datasets.2
In MouseOS™: location and season are attached to every session, multi-site studies can be compared side by side, and Virtual Control Groups can match by site and season.

Ultrasonic Vocalizations · Evidence: strong for affect in rats
What it measures: with the optional USV Microphone Kit ($300, requires Data Logger or Data Logger S), ultrasonic calls during each session, plus any ultrasonic noise from nearby equipment.
Why it matters: in rats, 22 kHz calls accompany negative states and 50 kHz calls positive ones.2021 Deep-learning tools now detect and classify these calls automatically.22 The evidence is strongest in rats, and USVs are not a validated readout of chronic pain.23
In MouseOS™: calls are time-aligned with video, summarized per session as covariates, and equipment ultrasound is flagged as an environmental event.
In MouseOS™
Every reading lands in MouseOS™ with the session it belongs to. Nothing to export, merge or line up by hand.
One Module, Any Experiment

Add Data Logger to PolarEye™, which already has an edge AI computer built in, and it adds the environmental record around each session. Or link it to other laboratory equipment and recording devices. Either way, it runs in a software environment such as MouseOS™, RatOS™ or AnimalOS™.
Build your system, then buy online or generate a quote.
Data Logger S · Standalone
Data Logger S is the standalone version of Data Logger. Its built-in touchscreen starts and saves each recording session, and every session is written to a USB drive or SD card.
$6,000 academic · $12,000 enterprise · Part no. DL1A-0S
Build your system, then buy online or generate a quote.
Why Record Everything
Most of what happens around an in vivo experiment is never written down. Data Logger S records it automatically, every session, so the conditions behind each result are documented instead of remembered.
FAQ
No. It works as an add-on to PolarEye™, which has an edge AI computer built in, or linked to other laboratory equipment and recording devices. It does need a software environment to run in, such as MouseOS™, RatOS™ or AnimalOS™.
Yes. The USV Microphone Kit ($300) requires Data Logger or Data Logger S.
Data Logger works with PolarEye™ or other laboratory equipment and runs in a software environment such as MouseOS™, RatOS™ or AnimalOS™. Data Logger S is standalone: you start and save sessions on its own touchscreen, and it records to a USB drive or SD card. Data Logger is $5,000 academic or $10,000 enterprise; Data Logger S is $6,000 academic or $12,000 enterprise.
Detailed specifications are coming soon and will be posted here.
No. Each variable on this page is labeled with the strength of its published evidence. Some, like outside weather and thunderstorms, are recorded so you can test them in your own data.
References